Leading Distributor / Channel Partner of vng-rw-800 and dream warmer from Rangareddy.

VNG-RW-800

REQUEST CALLBACK

VNG-RW-800
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 38,000 / PieceGet Latest Price

Features: - Heater Module

The radiant energy directed by the parabolic reflectors on the infant. The radiant energy can also be controlled either manually or by mean of skin temp sensor which controls the radiant energy to maintain a selected skin temperature.

Controller

When operated in manual control mode, the controller permits the operator to adjust the heat output of the heater module from zero to maximum settings. Thus, during the manual mode a patient probe can be used to monitor the skin temperature. Moreover, when operated in skin temperature control mode, the controller utilizes a skin temperature probe connected in between the controller input and the infant to automatically adjust the heat output of the heater module to maintain a selected preset skin temperature. Up and down switches permit adjustment of skin temp set point and a digital display provides temperature read out.

Examination light

·         Dazzle-free observation light for examination of the infant.

·         Also, the dual side swivel heater provided access for x- ray and other procedure.

Apgar timer

·         This mode used to take the infant Apgar score within specified time.

·         Also, in this mode one can start and stop, just press Apgar switch.

Alarm

Each time the unit is turned on, an automatic test sequence is initiated to verify that the visual display and the audible alarms are functional. Alarms are provided for high and low skin temperature.

Set point (high)

If the temp sensed by the skin probe is 0.5 degree above the set temperature, a high set point alarm will occur after a delay of 10 second. In addition, the audible portion of the alarm can be silenced by depressing the alarm mute switch. However, the visual indicator will continue. If the condition is not corrected within 20 sec the audible alarm will resume. When the alarm condition is corrected, the circuit will reset.

Set point (low)

If the set temperature sensed by the skin probe is 0.5 degree less than the set point, a low set point alarm will occur after a delay of 10 seconds.

Probe fails

During skin control mode, if the skin temp probe opens short or un-plugged, the probe failure alarm will indicate the baby temperature display and the heater will be turned off. This alarm cannot be rest until the alarm condition is corrected.

 

Warmer-Modes of Operation: -

1.       Servo mode

2.       Manual mode
3. Air Mode

Yes! I am Interested

DREAM WARMER

REQUEST CALLBACK

DREAM WARMER
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 16,000 / PieceGet Latest Price

Features:

·         Its unique design makes it easy for medical staff and parents to access the baby since there is no fabric attached.

·         Also, wash it easily with hands even in environments where diapers or washing machines are unavailable.

·         In addition to the mattress, the insulating pad and thermos contain simple instructions so that even those with limited literacy abilities to understand them.

Also, used in the delivery room for neonatal resuscitation, home, or transportation to a higher level of care. It can be used for neonatal resuscitation in the delivery room.
Yes! I am Interested

X


Explore More Products

Contact via E-mail
Contact via SMS
Inukonda Rajkiran Reddy (CEO)
Medq India
3-8-341/1, Plot No.20,Chandrapuri, Colony Autonagar, L.B.Nagar,Hyderabad,Habsiguda
Rangareddy - 500074, Telangana, India
Call Us: 
Call Response Rate: 76%
Share Us :



© Medq India. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Medq India